Steam temperature (was meniscus mayhem)

2001-06-01 Thread Shyvers, Steve
Walt and the List: According to Properties of Saturated Steam data from the 1991 Brooks Instruments catalog, saturated steam temperatures for various pressures (psig) will be: PSIGTemp (F) 0.0 212.00 20.3259.28 40.3287.07 60.3307.60 I

Re: Steam temperature (was meniscus mayhem)

2001-06-01 Thread WaltSwartz
Steve, My fuzzy logic (Balvenie fortified) seems to think there is some sort of temperature gradient, otherwise all the water would flash to steam unless the increasing vapor pressure keeps the water from shifting phase, requiring greater heat input per unit to increase the temp to make more

RE: Steam temperature (was meniscus mayhem)

2001-06-01 Thread Shyvers, Steve
Walt, I believe that your statement the increasing vapor pressure keeps the water from shifting phase, requiring greater heat input per unit to increase the temp to make more steam is correct. As the boiler continues to be fired the temperature and pressure both rise until the safety blows.