On 30 April 2018 at 06:32, Miika Turkia wrote:
> On Mon, Apr 30, 2018 at 2:44 AM, Lubomir I. Ivanov
> wrote:
>>
>> On 30 April 2018 at 02:29, Dirk Hohndel wrote:
>> > So builds for that currently fail - Normally we download those
Hi all,
I was playing with 4.7.8 on Windows 7 and I noted a couple of things:
- I cannot see anymore pO2 sensor from my Petrel controller. No average pO2
nor individual. On preference tab I have individual and setpoint option
checked nad the toolbar has O2 toggled
The last time I saw them it
On Mon, 30 Apr 2018 at 13:45, Willem Ferguson <
willemfergu...@zoology.up.ac.za> wrote:
> On 30/04/2018 12:20, Davide DB wrote:
> > On the
> > contrary the Shearwater desktop/mobile download is always 100% reliable.
> > ___
> > subsurface mailing list
On 30/04/2018 12:20, Davide DB wrote:
On the
contrary the Shearwater desktop/mobile download is always 100% reliable.
___
subsurface mailing list
subsurface@subsurface-divelog.org
Maibe shearwater support should be informed?? For me using their win
application always fails. My other friend who has latest perdix did not
even once succeded in connecting to computer.
On Mon, Apr 30, 2018, 13:21 Davide DB wrote:
> As final user I can do no other than
As final user I can do no other than express my utmost appreciation for
you guys trying to untangle this mess fo BT Petrel stack, OS version and
Libdivecomputer.
Without going deeper into Subsurface download it's clear to me that the
problem starts with the Android BT pairing already.
With my