Re: Importing from two computers with air pressure sensors

2020-06-12 Thread Dirk Hohndel via subsurface
Not something we have ever considered as a use case. If you have four different gas mixes, it should work. If some of the tanks have the same mix, it will assume that you are importing the same dive with the same two tanks from two different computers (as many of us dive with one or more backup

Re: Importing from two computers with air pressure sensors

2020-06-12 Thread Richard Houser via subsurface
Would this be a simple enough check?: IF (start/end pressure are BOTH within X% of an existing cylinder) THEN treat as the same, ELSE add as new? On Fri, Jun 12, 2020, 15:17 Dirk Hohndel via subsurface < subsurface@subsurface-divelog.org> wrote: > Not something we have ever considered as a

Re: Importing from two computers with air pressure sensors

2020-06-12 Thread Linus Torvalds via subsurface
On Fri, Jun 12, 2020 at 11:57 AM John Smith via subsurface wrote: >  > I have two Shearwaters that can record gas pressure, so in theory can > monitor four cylinders at the same time. So as Dirk mentioned, the subsurface default assumption is that when you have multiple dive computers with gas s

Re: Importing from two computers with air pressure sensors

2020-06-12 Thread Linus Torvalds via subsurface
On Fri, Jun 12, 2020 at 1:01 PM Richard Houser via subsurface wrote: > > Would this be a simple enough check?: > > IF (start/end pressure are BOTH within X% of an existing cylinder) THEN treat > as the same, ELSE add as new? We could change our heuristics, but part of it is that we very much hav