Re: [Elphel-support] stereo camera with BW CCD

2013-09-19 Thread Oleg
Hello Daniel, 1. Setting the WOI: 1a. Set the width (doesn't work correctly in camvc - so, Parameter Editor > multisensor): I could reproduce your problem - that's a bug. Notes and temporary solution: 1a1. It's ok to change WOI_WIDTH only. 1a2. If the image is scrambled - setting WOI_WIDTH to 5

Re: [Elphel-support] stereo camera with BW CCD

2013-09-10 Thread drouan
Of course, this is not my top priority project in the coming weeks. Thanks again. Daniel Le 10 sept. 2013 à 07:36, support-list a écrit : > This is really strange, we'll have to try to reproduce it. Oleg is on > vacation until September, 17 - he worked most with the stereo setup. He

Re: [Elphel-support] stereo camera with BW CCD

2013-09-09 Thread drouan
Andrey, Le 7 sept. 2013 à 20:37, support-list a écrit : > Imgsrv has "/trig" command that issues a single trigger if the camera is set > to single trigger mode, but for testing of the corrupted images it may be > simpler to just use some definitely slow fps (like 1 FPS) by setting > TRIG_PE

Re: [Elphel-support] stereo camera with BW CCD

2013-09-07 Thread support-list
Daniel, The imgsrv - image server on port 8081 has a mini-help page - just open http://:8081 page. This server is for manipulation data in the circular buffer, it also does not depend on the main lighttpd that can get stuck when there are several instances of the PHP busy waiting for

Re: [Elphel-support] stereo camera with BW CCD

2013-09-07 Thread drouan
Le 5 sept. 2013 à 23:44, support-list a écrit : > Daniel > > For FPS control I meant using TRIG=4 as described in > http://wiki.elphel.com/index.php?title=Trigger > TRIG_CONDITION=0 means that the FPGA timer will generate trigger pulses, not > the external connector OK, this is the basic si

Re: [Elphel-support] stereo camera with BW CCD

2013-09-05 Thread support-list
Daniel For FPS control I meant using TRIG=4 as described in http://wiki.elphel.com/index.php?title=Trigger TRIG_CONDITION=0 means that the FPGA timer will generate trigger pulses, not the external connector Did you try to change height after reducing width (and getting bad images)? Do both sen

Re: [Elphel-support] stereo camera with BW CCD

2013-09-05 Thread drouan
Thanks Andrey, Le 5 sept. 2013 à 09:36, support-list a écrit : > >In fact for my application, I had to buy (at some Chinese website) longer > >cables and I just installed only one on one channel, keeping the original > >medium long on the other: is it a possible cause of the problem ? > > D

Re: [Elphel-support] stereo camera with BW CCD

2013-09-05 Thread support-list
>In fact for my application, I had to buy (at some Chinese website) longer cables and I just installed only one on one channel, keeping the original medium long on the other: is it a possible cause of the problem ? Daniel, yes - it can cause problem - those that are visible on the first image.

Re: [Elphel-support] stereo camera with BW CCD

2013-09-05 Thread support-list
Dear Daniel, I'm sorry but I just found out that we do not have any asembled stereo cameras around to reproduce the problem, we plan to have on in 2-3 weeks. So le's try to troubleshoot the problems with your camera. What we can try first is to isolate - is that wrong geometry setting or wrong

Re: [Elphel-support] stereo camera with BW CCD

2013-09-05 Thread drouan
Dear Andrey, Thanks for the advices: I'll do what you suggest. Le 5 sept. 2013 à 06:25, support-list a écrit : > I also noticed the another problem on the first image - wrong sensor board > phase adjustment (it depends on the cable length that is longer in stereo > cameras). Oleg did such ad

Re: [Elphel-support] stereo camera with BW CCD

2013-09-04 Thread drouan
Dear Andrey, Here: https://upload.obspm.fr/get?k=OKsc283yHuLvGsNuOFu are the pdf of three parameters/init pages (parameters editor): Parameters_init0 : is the standard configuration after a cold start ; full size, the images are "normal"; note that the parameters MULTI_WIDTHn and are not s

Re: [Elphel-support] stereo camera with BW CCD

2013-09-03 Thread support-list
Dear Daniel, It is definitely possible to run smaller WOI on the camera, can you please send some detailed step-by-step instructions so we can reproduce your case and get the same errors? The camera GUI interface (camvc) is a rather old application that was updated to accommmodate new sensor c

Re: [Elphel-support] stereo camera with BW CCD

2013-09-03 Thread drouan
Dear Andrey and Oleg, After a lot of testing I'll try to be more specific. I'm not sure that the problem comes from the de-Bayer process. Probably no. My goal is to acquire (through the disk recorder for instance) simultaneous images of the two Black and White 2592x1944 Aptina sensors of the

[Elphel-support] stereo camera with BW CCD

2013-08-23 Thread drouan
Hello Oleg, I purchased a stereo configuration equipped with Black and white CCDs. I want to do as fast as possible image acquisition in reduced format. Unfortunately, using the camera control interface (camvc / tab 5) , the images become ugly because some de-Bayer process try to use the color