Author: jchandra Date: Sun Oct 21 02:12:26 2018 New Revision: 339517 URL: https://svnweb.freebsd.org/changeset/base/339517
Log: arm generic_timer: fix armv8 timer desc In the FDT based probe, check for "arm,armv8-timer" before "arm,armv7-timer". This gets the description right when the timer node has both entries in compatible list. Modified: head/sys/arm/arm/generic_timer.c Modified: head/sys/arm/arm/generic_timer.c ============================================================================== --- head/sys/arm/arm/generic_timer.c Sun Oct 21 02:08:57 2018 (r339516) +++ head/sys/arm/arm/generic_timer.c Sun Oct 21 02:12:26 2018 (r339517) @@ -323,11 +323,11 @@ arm_tmr_fdt_probe(device_t dev) if (!ofw_bus_status_okay(dev)) return (ENXIO); - if (ofw_bus_is_compatible(dev, "arm,armv7-timer")) { - device_set_desc(dev, "ARMv7 Generic Timer"); - return (BUS_PROBE_DEFAULT); - } else if (ofw_bus_is_compatible(dev, "arm,armv8-timer")) { + if (ofw_bus_is_compatible(dev, "arm,armv8-timer")) { device_set_desc(dev, "ARMv8 Generic Timer"); + return (BUS_PROBE_DEFAULT); + } else if (ofw_bus_is_compatible(dev, "arm,armv7-timer")) { + device_set_desc(dev, "ARMv7 Generic Timer"); return (BUS_PROBE_DEFAULT); } _______________________________________________ svn-src-all@freebsd.org mailing list https://lists.freebsd.org/mailman/listinfo/svn-src-all To unsubscribe, send any mail to "svn-src-all-unsubscr...@freebsd.org"