> Rainer,
> 
> FWIIW, I've seen Netscreen, NetGear and some LinkSys devices send a Null
> character at the end of each message. Not all versions of the firmware would
> include the Null at the end which leads me to believe it may be a bug in
> some releases of the firmware.
> 
> When sending syslog over TCP, Netscreen firewalls will delimit each message
> with LF NULL.
> 
> This probably won't have any impact on the 'CLR' since it is the very last
> character in the message, but I thought I would raise the issue with you as
> a real-life case of a Null character being used.

Buggy software does not equate to a "real-life case".

But to judge whether or not it is a bug requires knowing what their
protocol spec is.

In this case, it is a delimeter and that is not something that requires
escaping.  In fact, it would be a bug to escape it if it were being used
in this manner.

Darren