RE: TeraScript-Talk: TeraScript 6.2.7 [Advanced Edition] 30 seconds freeze when timing out variables, on Windows Server platform

2017-07-24 Thread Andrej Popovic
Shubert [mailto:rshub...@tronics.com] Sent: 21 July 2017 14:45 To: TeraScript-Talk@terascript.com Subject: RE: TeraScript-Talk: TeraScript 6.2.7 [Advanced Edition] 30 seconds freeze when timing out variables, on Windows Server platform There may be a connection there. The VTT uses an internal http web

RE: TeraScript-Talk: TeraScript 6.2.7 [Advanced Edition] 30 seconds freeze when timing out variables, on Windows Server platform

2017-07-21 Thread Robert Shubert
. Robert From: Andrej Popovic [mailto:and...@workflowengine.co.uk] Sent: Friday, July 21, 2017 5:56 AM To: TeraScript-Talk@terascript.com Subject: TeraScript-Talk: TeraScript 6.2.7 [Advanced Edition] 30 seconds freeze when timing out variables, on Windows Server platform Hi all I am observing

TeraScript-Talk: TeraScript 6.2.7 [Advanced Edition] 30 seconds freeze when timing out variables, on Windows Server platform

2017-07-21 Thread Andrej Popovic
Hi all I am observing TeraScript 6.2.7 [Advanced Edition] on Windows Server pausing all processing when timing out session variables for a user session. The pause is always around 30 seconds and affects all TeraScript threads. It would seem to be connected with using variableTimeoutTrigger