Re: [Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Vasily Vl. Suhachev via Therion
Hello I found some trick to fix XVI wrong placement problem On a dedicated XVI thconfig use such commands source   centerline     fix 62@stels1.stels 0 0 0   endcenterline endsource Station to fix is should be upper station in current elevation XVI Please test this workaround... I hope it is

Re: [Therion] Therion compiles but overwrites log file

2018-01-05 Thread Bruce Mutton via Therion
Thanks Stacho 5.4.1+d281f25 (2017-12-29) has resolved this (discarding of log file contents) for the projects that it was affecting. Those projects still raise the "warning -- error deleting temporary directory" but at least now I have a valid log file. Will perhaps help me to track down

Re: [Therion] Group text request

2018-01-05 Thread Bruce Mutton via Therion
Thanks Stacho Looks like 5.4.1+d281f25 (2017-12-29) has resolved this. Bruce From: Therion [mailto:therion-boun...@speleo.sk] On Behalf Of Bruce Mutton via Therion Sent: Tuesday, 26 December 2017 11:03 AM To: 'List for Therion users' Cc: Bruce Mutton

Re: [Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Evaristo Quiroga via Therion
Hi, Like Vasily, I have found only the morphed extended XVI file are wrong, the plan XVI file are OK.  The problem is a error in the calculation of the Sketch Y coordinate  . The coordinate information is in the XVI file, this the reason because any change in Xtherion map editor don't solve

Re: [Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Evaristo Quiroga via Therion
Hi Xavier, Thanks for the link, previously I don't found anything  because I have searched "morphing extended profile". I experienced the sames problems you have described. If you move manually the sketch in Xterion map editor, you have to do again every time you open the .th2 file.  I

Re: [Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Xavier Pennec via Therion
Dear Evaristo, There is a bug that has been first raised in 2011 and that has still been discussed last year (https://mailman.speleo.sk/pipermail/therion/2016-December/006121.html). I guess that this is what you are referring to. I do not think this is normal too but I know no other solution

[Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Evaristo Quiroga via Therion
Hi, I have this problem: the xviresult file of the morphing processwith extended profiles is erroneous. The centerline and sketch don't are superposed. The xvi is at 0 0 position, but the sketch are very displaced in Y direction (X it's OK), far 35000 units. I can do a manual solution

[Therion] Error morphing scanned extended profiles survey sketches

2018-01-05 Thread Evaristo Quiroga via Therion
Hi, I have this problem: the xviresult file of the morphing processwith extended profiles is erroneous. The centerline and sketch don't are superposed. The xvi is at 0 0 position, but the sketch are very displaced in Y direction (X it's OK), far 35000 units. I can do a manual solution