Re: [time-nuts] HP 53132A Display

2016-04-02 Thread Esa Heikkinen
Bert Kehren via time-nuts kirjoitti: Did buy a HP53132a counter mainly to use with the RS 232 for high resolution and to have a backup for my very favorite 5345a with 40 GHz head. Sadly the very clean unit has a very weak display to the extend that an 8 looks like a 9. Have the option for a

Re: [time-nuts] HP 53132A Display

2016-04-01 Thread Philip Zahariev via time-nuts
Hi Bert, Disconnect filament from PCB (one end is enough) and connect to regulated DC Power supply. Adjust voltage to 8V and current to 0.3-0.4A. In a dark room should see very small red light. Slowly increase little bit voltage until color goes to orange-yellow. Important - do not move display

Re: [time-nuts] HP 53132A Display

2016-04-01 Thread Rob Sherwood .
, 2016 1:14 PM To: time-nuts@febo.com Subject: [time-nuts] HP 53132A Display Did buy a HP53132a counter mainly to use with the RS 232 for high resolution and to have a backup for my very favorite 5345a with 40 GHz head. Sadly the very clean unit has a very weak display to the extend that an 8

[time-nuts] HP 53132A Display

2016-04-01 Thread Bert Kehren via time-nuts
Did buy a HP53132a counter mainly to use with the RS 232 for high resolution and to have a backup for my very favorite 5345a with 40 GHz head. Sadly the very clean unit has a very weak display to the extend that an 8 looks like a 9. Have the option for a full refund but would like to explore