I have a Trimble Palisade that may have become faulty. It will no longer
come up from "cold" (power on) and lock on to any satellites.
It does respond on both serial ports and works with PalisadeMonitor (on
port B) - I can upload time, position and almanac to it, after which it
shows which satellites it is tracking. The trouble is my almanac file is
now 6 months old (dumped from the GPS at a time when it was working).
Before giving up on it, I'd like to try uploading a fresh almanac.dat
file (perhaps dumped from a working unit), just in case this improves
its chance of getting a fix ... or if anyone knows of s/w to convert
available almanac formats into the binary file that PalisadeMonitor uses
I'd be very grateful.
Finally, if anyone knows what is possible using the Clear/Set CLock
Offset "service" commands I'd like to learn more. The clock offset
always displays as (about) -1500 Hz at startup and stays that way most
of the time. I have written a program to manually set this to other
values in the hope that changing the clock offset manually (perhaps
together with a recent almanac) might get the unit working again.
So far I've had the unit out of doors for several days without it
properly acquiring any satellites.
Optimistically yours,
Steve Platt, G4WSZ
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.