I have a Trimble Palisade that may have become faulty. It will no longer come up from "cold" (power on) and lock on to any satellites.

It does respond on both serial ports and works with PalisadeMonitor (on port B) - I can upload time, position and almanac to it, after which it shows which satellites it is tracking. The trouble is my almanac file is now 6 months old (dumped from the GPS at a time when it was working).

Before giving up on it, I'd like to try uploading a fresh almanac.dat file (perhaps dumped from a working unit), just in case this improves its chance of getting a fix ... or if anyone knows of s/w to convert available almanac formats into the binary file that PalisadeMonitor uses I'd be very grateful.

Finally, if anyone knows what is possible using the Clear/Set CLock Offset "service" commands I'd like to learn more. The clock offset always displays as (about) -1500 Hz at startup and stays that way most of the time. I have written a program to manually set this to other values in the hope that changing the clock offset manually (perhaps together with a recent almanac) might get the unit working again.

So far I've had the unit out of doors for several days without it properly acquiring any satellites.

Optimistically yours,
Steve Platt, G4WSZ

_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to