Hi Ulf
Also you noted the bulb had the thermionic device, That's used for
remigrating the Rb into the reservoir there is a procedure for doing it in the
manuals on the web.
It can take up to a week to draw all the Rb back into the reservoir after long
inactivity.Just make sure you use a
Totally agree with Scott.
On the lamp thats good it lights.
If you search older threads on Time-nuts you will see that on the FRS
rubidiums you can heat the lamp with a heat gun and re-migrate the RB off
of the glass. It makes them re-usable and extends the life very nicely.
I do not suggest doing
I would say fix both units
The color of the bulb is simply Rb vapor condensed on the walls of the envelope.
10811 units are fairly common at good hamfests and ebay
Content by Scott
Typos by Siri
> On Sep 12, 2017, at 4:54 PM, Ulf Kylenfall via time-nuts
> wrote:
>
>
> What does the communit
Picked up a scrapped 5065A tonight.
It was an early unit but a later one than the one I amtrying to fix.
The XO was gone. From what I could see, it had beena 10811 type with adapterĀ
since there was no 115V wiring.
The RV Cavity was loose and I think that what was in this unit mayhave been a
rep