Here is the exact output from my XLi. There are extra lines for F18 and F72
but not F73.
>F18
F18 BOOTLOADER 192-8000
SOFTWARE192-8001
FILE SYSTEM 192-8002V2.0
PROJ REV # 2.0
FPGA # 184-8000V64
>F72
F72 CLOCK PLL LOCKED
CLOCK STATUS
Ive got one as well, i’ll look at it over the weekend but as I recall these
are all string outputs which require parsing. The problem with fault and alarm
is without manual dont have a list of possible faults and alarms
Version is easy its the same as displayed on LCD
Content by Scott
Typos b
On 2019-05-16 20:13, Mark Sims wrote:
I am in the process of adding Truetime XL (DC and AK) support to Lady
Heather. It looks like I can also support the XLi (does NTP), but the
XLi manual has some vague/conflicting info for the output of these
commands:
F18 - version
F72 - faults
F73 - alarms
I am in the process of adding Truetime XL (DC and AK) support to Lady Heather.
It looks like I can also support the XLi (does NTP), but the XLi manual has
some vague/conflicting info for the output of these commands:
F18 - version
F72 - faults
F73 - alarms
Does anybody have an XLi and can capt