Hi all,
Is there any way we can get an feed for the main TinyOS news page?
I've noticed that the scoop application can generate an rdf feed (eg.
http://www.kuro5hin.org/backend.rdf ).
I'm not sure if its a simple thing for the webmaster to enable, but if
it is, it would be great - I like keeping
Hi All,
I'm trying to make the ultrasound sensors of cricket motes work with a
simple application. I have a couple of motes, each one with its own REPEAT
timer of 1 second. Every time the timer fires the mote send a pulse. The
detector is started and, restarted everytime the timeout occours, in or
Hello;
I feel so bad for not thinking about the chance they were debug messages, I
assumed they were only used for TOSSIM or something like that, not for the
real implementation. Anyway, it did the trick and I got out of the messages.
What intrigues me now is the content of the messages themselv
Hello,
can anyone help me, regarding this problem, " failed to create temporary
File".Sometimes i get this error and sometimes the program is compiling
successfully.Dont know why?
Can anyone help me?
Thanks,
Mahesh Satharla.
On 5/22/07, maheshbabu satharla <[EMAIL PROTECTED]> wrote:
Hi,
I a
The MDA300 doesn't expose any RS-232 interface.
The MICA Motes do have 2 UART interfaces (different voltage levels than
RS232) that have shared functionality. You need to first convert your
RS-232 levels into 0-3V levels before connecting to one of these UART
interfaces.
You should be able to use
Hi all,
I want to know what is the max sampling rate for the digital channel of MDA300
board? I want to use one of the digital channel to interface with RS232 serial
port because the particular sensor we got use digital signal with RS232
interface. I heard that the digital channel sampling rate
Danielle,
While I cannot give you precise answer for the expected output on the
MicaZ, I can describe our experiences on Tmote Sky, which uses the
same CC2420. The valid values for CC2420 power setting seem to range
between 1 and 31, and they all seem to affect the output power. It
looks like t
On May 25, 2007, at 8:10 AM, Philip Levis wrote:
In 2.0.1, the best way to figure this out is to enable the dbg
channel "SNRLoss". It won't tell you exactly what you want --
there's some additional information in there -- but I think that if
you trim its output a bit (e.g., add another ch
On May 25, 2007, at 6:38 AM, Matthias Gauger wrote:
Hello,
Is there a way to detect and log the occurrence of collisions
causing packet loss in TOSSIM when using Tinyos 2.0? I couldn't
find any information on that in the TOSSIM tutorial.
Because TOSSIM in 2.0 uses an SNR model, doing this
Hi,
I'm trying to get count PowerTossim CPU cycles. I've followed the
instructions at
http://www.eecs.harvard.edu/~shnayder/ptossim/install.html and
http://www2.uic.edu/~tcanli1/cpucyclecountingcode.htm, but keep on
getting zero values for my CPU cycle count.
I suspect that this may be rel
Hello,
Is there a way to detect and log the occurrence of collisions causing
packet loss in TOSSIM when using Tinyos 2.0? I couldn't find any
information on that in the TOSSIM tutorial.
Thanks,
Matthias
___
Tinyos-help mailing list
Tinyos-help@Mi
* Munaretto, Daniele:
>In the MPR-MIB user's manual (rev.B), at page 24, there is a table with some
>Power Register code and the corresponding TX RF power in dBm.
>
>Unfortunately not all the codes have the corresponding.
>
>Does anyone know the RF power when using the lowest code number, e.g. 0?
* Bernardo Avila Pires:
>CC1000Const.h and I've found the
>#ifndef CC1E_DEF_PRESET
>#define CC1E_DEF_PRESET (CC1E_915_998_MHZ)
>#endif
>
>But with another frequency value. What happens is that this file is in two
>folders, one suffixed with _lpl. What does it mean?
I think "lpl" stands for "low po
Hi Sarfraz,
I am afraid I did not elaborate. Not only the serialforwarder complains
but I get this output message with simcore.sim.stop() enabled:
SimComm: TossimInitEvent received (10 motes)... initializing system.
SimComm: Pausing system for TossimInitEvent
status: Simulation paused
Starting
Hi Junyan,
we did try setting the identical fuse bits, bit still had no success.
the procedure we followed was---
1. use tinyos make and avr-objcopy to generate am ihex file for mica2.
2. read the fuse bits from a mica2
3. set identical fuse bits for out platform via icc-avr
4. flash the ihex cod
Dear all,
In the MPR-MIB user's manual (rev.B), at page 24, there is a table with some
Power Register code and the corresponding TX RF power in dBm.
Unfortunately not all the codes have the corresponding.
Does anyone know the RF power when using the lowest code number, e.g. 0?
Because 3
Thank you very much!
Cheers
Daniele
Daniele Munaretto
Researcher
DoCoMo Communications Laboratories Europe GmbH
Landsbergerstraße 312 80687 Munich Germany
Mobile : +49- 162- 2919-218
Office : +49- 89- 56824-218
Fax : +49- 89- 56824-300
17 matches