Re: [PATCH] configs: Increase malloc size after relocation

2023-01-11 Thread Neha Malcom Francis
Hi Vignesh, On 11/01/23 14:55, Vignesh Raghavendra wrote: On 11/01/23 11:34, Neha Malcom Francis wrote: Current default size of 0x10 is not capable of getting the FIT buffer during boot when transitioning to using binman generated boot images for certain K3 devices, so increase it to

Re: [PATCH] configs: Increase malloc size after relocation

2023-01-11 Thread Vignesh Raghavendra
On 11/01/23 11:34, Neha Malcom Francis wrote: > Current default size of 0x10 is not capable of getting the FIT > buffer during boot when transitioning to using binman generated boot > images for certain K3 devices, so increase it to 0x40. Since A72 SPL > is coming after relocation to

[PATCH] configs: Increase malloc size after relocation

2023-01-10 Thread Neha Malcom Francis
Current default size of 0x10 is not capable of getting the FIT buffer during boot when transitioning to using binman generated boot images for certain K3 devices, so increase it to 0x40. Since A72 SPL is coming after relocation to DDR this should not be an issue for any K3 device, so make