Send the Labgrid quit characters to ask it to exit gracefully. This typically allows it to power off the board being used.
If that doesn't work, try the less graceful approach. Signed-off-by: Simon Glass <s...@chromium.org> --- test/py/u_boot_spawn.py | 17 +++++++++++++++-- 1 file changed, 15 insertions(+), 2 deletions(-) diff --git a/test/py/u_boot_spawn.py b/test/py/u_boot_spawn.py index 261bdf62e15..000e2a364e4 100644 --- a/test/py/u_boot_spawn.py +++ b/test/py/u_boot_spawn.py @@ -16,6 +16,9 @@ import termios import time import traceback +# Character to send (twice) to exit the terminal +EXIT_CHAR = 0x1d # FS (Ctrl + ]) + class Timeout(Exception): """An exception sub-class that indicates that a timeout occurred.""" @@ -301,15 +304,25 @@ class Spawn: None. Returns: - Nothing. + str: Type of closure completed """ + self.send(chr(EXIT_CHAR) * 2) + # Wait about 10 seconds for Labgrid to close and power off the board + for _ in range(100): + if not self.isalive(): + return 'normal' + time.sleep(0.1) + + # That didn't work, so try closing the PTY os.close(self.fd) for _ in range(100): if not self.isalive(): - break + return 'break' time.sleep(0.1) + return 'timeout' + def get_expect_output(self): """Return the output read by expect() -- 2.34.1