Hi Sebastian,
On 02.11.20 09:07, Stefano Babic wrote:
Hi Sebastian,
I integrated the patches but the MAINTAINERS file for B1x5v2 is missing.
Can you send a follow-up patch to fix this ? (Or just a V5 for 9/9, your
choice).
Just send a follow-up patch, thanks.
Regards,
Stefano
Regards,
S
Hi Sebastian,
I integrated the patches but the MAINTAINERS file for B1x5v2 is missing.
Can you send a follow-up patch to fix this ? (Or just a V5 for 9/9, your
choice).
Regards,
Stefano
On 02.09.20 19:31, Sebastian Reichel wrote:
This series introduces support for a new i.MX6DL based GE pat
Hi Sebastian,
On Wed, Sep 2, 2020 at 2:31 PM Sebastian Reichel
wrote:
>
> This series introduces support for a new i.MX6DL based GE patient
> monitor series.
>
> Patch 1: Add support for storing bootcount in SPI-flash
> Patch 2+3: Improve M41T62 RTC driver's reset routine.
> PATCH 4: Support disa
This series introduces support for a new i.MX6DL based GE patient
monitor series.
Patch 1: Add support for storing bootcount in SPI-flash
Patch 2+3: Improve M41T62 RTC driver's reset routine.
PATCH 4: Support disable_ldb_di_clock_sources for i.MX6DL
Patch 5: Add poweroff-gpio support
Patch 6-8: re