From: Jan Kiszka <jan.kis...@siemens.com> Without CONFIG_LED, we get
cmd/built-in.o: In function `show_led_state': cmd/led.c:40: undefined reference to `led_get_state' cmd/built-in.o: In function `do_led': cmd/led.c:99: undefined reference to `led_get_by_label' cmd/led.c:108: undefined reference to `led_set_state' Signed-off-by: Jan Kiszka <jan.kis...@siemens.com> --- cmd/Kconfig | 1 + 1 file changed, 1 insertion(+) diff --git a/cmd/Kconfig b/cmd/Kconfig index ea1a325eb3..e1c0719165 100644 --- a/cmd/Kconfig +++ b/cmd/Kconfig @@ -1399,6 +1399,7 @@ config CMD_DISPLAY config CMD_LED bool "led" + depends on LED default y if LED help Enable the 'led' command which allows for control of LEDs supported -- 2.16.4 _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot