From: Jan Kiszka <jan.kis...@siemens.com>

Without CONFIG_LED, we get

cmd/built-in.o: In function `show_led_state':
cmd/led.c:40: undefined reference to `led_get_state'
cmd/built-in.o: In function `do_led':
cmd/led.c:99: undefined reference to `led_get_by_label'
cmd/led.c:108: undefined reference to `led_set_state'

Signed-off-by: Jan Kiszka <jan.kis...@siemens.com>
---
 cmd/Kconfig | 1 +
 1 file changed, 1 insertion(+)

diff --git a/cmd/Kconfig b/cmd/Kconfig
index ea1a325eb3..e1c0719165 100644
--- a/cmd/Kconfig
+++ b/cmd/Kconfig
@@ -1399,6 +1399,7 @@ config CMD_DISPLAY
 
 config CMD_LED
        bool "led"
+       depends on LED
        default y if LED
        help
          Enable the 'led' command which allows for control of LEDs supported
-- 
2.16.4