Stuart,

Does changing the BlockSize help? I guess making it smaller *may* help?
Never used it myself... 

Regards,
David


-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Boydell, Stuart
Sent: Wednesday, June 27, 2007 8:55 PM
To: u2-users@listserver.u2ug.org
Subject: [U2] UniCommand NextBlock inter-time

Using UniCommand.Execute / NextBlock to get chunks of data from a UV
server there seems to be up to a minute between fetches. The NextBlock
code is sitting in a hard loop and the servers (source & target) seem to
be fairly quiescent for most of this time - so it doesn't appear to be a
load issue. Does anyone know if this is a tuneable parameter?
Regards,
Stuart Boydell
-------
u2-users mailing list
u2-users@listserver.u2ug.org
To unsubscribe please visit http://listserver.u2ug.org/

Reply via email to