[Bug 1273907] Re: multiple cups daemons running

2014-10-28 Thread Alexey Zagarin
Also had this issue. The problem here is that one or some of the configuration utilities (could be hplip tools also) restarts cups at some point by calling /etc/init.d/cups restart. Since cups startup scripts were converted to upstart jobs, at the moment of restart upstart will notice that there

[Bug 1273907] Re: multiple cups daemons running

2014-03-30 Thread Launchpad Bug Tracker
[Expired for cups (Ubuntu) because there has been no activity for 60 days.] ** Changed in: cups (Ubuntu) Status: Incomplete = Expired -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1273907

[Bug 1273907] Re: multiple cups daemons running

2014-01-29 Thread Till Kamppeter
Usually this should not be possible, as there cannot be two daemons listening on port 631 and possibly also not two daemons sharing the /var/run/cups/cups.sock socket. Can you follow the instructions of the section CUPS error_log on https://wiki.ubuntu.com/DebuggingPrintingProblems. Please also