Hi LakeShen

You also must assign IDs to all operators of an application. Otherwise, you may 
not be able to recover from checkpoint

Doc: 
https://ci.apache.org/projects/flink/flink-docs-stable/ops/upgrading.html#matching-operator-state
 
<https://ci.apache.org/projects/flink/flink-docs-stable/ops/upgrading.html#matching-operator-state>

Best Regards

jinhai...@gmail.com

> 2020年3月17日 下午5:51,Till Rohrmann <trohrm...@apache.org> 写道:
> 
> Let us know if you should run into any problems. The state processor API is 
> still young and could benefit from as much feedback as possible.
> 
> Cheers,
> Till
> 
> On Tue, Mar 17, 2020 at 2:57 AM LakeShen <shenleifight...@gmail.com 
> <mailto:shenleifight...@gmail.com>> wrote:
> Wow,this feature is look so good,I will see this feature.
> Thank you to reply me , Till😀.
> 
> Best Regards,
> LakeShen
> 
> Till Rohrmann <trohrm...@apache.org <mailto:trohrm...@apache.org>> 
> 于2020年3月17日周二 上午4:17写道:
> If you want to change the max parallelism then you need to take a savepoint 
> and use Flink's state processor API [1] to rewrite the max parallelism by 
> creating a new savepoint from the old one.
> 
> [1] 
> https://ci.apache.org/projects/flink/flink-docs-stable/dev/libs/state_processor_api.html
>  
> <https://ci.apache.org/projects/flink/flink-docs-stable/dev/libs/state_processor_api.html>
> 
> Cheers,
> Till
> 
> On Sat, Mar 14, 2020 at 4:07 AM LakeShen <shenleifight...@gmail.com 
> <mailto:shenleifight...@gmail.com>> wrote:
> Hi Eleanore , if you resume from savepoint , you can't change the flink
> operator's max parallelism .
> 
> Eleanore Jin <eleanore....@gmail.com <mailto:eleanore....@gmail.com>> 
> 于2020年3月14日周六 上午12:51写道:
> 
> > Hi Piotr,
> > Does this also apply to savepoint? (meaning the max parallelism should not
> > change for job resume from savepoint?)
> >
> > Thanks a lot!
> > Eleanore
> >
> > On Fri, Mar 13, 2020 at 6:33 AM Piotr Nowojski <pi...@ververica.com 
> > <mailto:pi...@ververica.com>>
> > wrote:
> >
> > > Hi,
> > >
> > > Yes, you can change the parallelism. One thing that you can not change is
> > > “max parallelism”.
> > >
> > > Piotrek
> > >
> > > > On 13 Mar 2020, at 04:34, Sivaprasanna <sivaprasanna...@gmail.com 
> > > > <mailto:sivaprasanna...@gmail.com>>
> > > wrote:
> > > >
> > > > I think you can modify the operator’s parallelism. It is only if you
> > > have set maxParallelism, and while restoring from a checkpoint, you
> > > shouldn’t modify the maxParallelism. Otherwise, I believe the state will
> > be
> > > lost.
> > > >
> > > > -
> > > > Sivaprasanna
> > > >
> > > > On Fri, 13 Mar 2020 at 9:01 AM, LakeShen <shenleifight...@gmail.com 
> > > > <mailto:shenleifight...@gmail.com>
> > > <mailto:shenleifight...@gmail.com <mailto:shenleifight...@gmail.com>>> 
> > > wrote:
> > > > Hi community,
> > > >       I have a question is that I cancel the flink task and retain the
> > > checkpoint dir, then restore from the checkpoint dir ,can I change the
> > > flink operator's parallelism,in my thoughts, I think I can't change the
> > > flink operator's parallelism,but I am not sure.
> > > >      Thanks to your reply.
> > > >
> > > > Best wishes,
> > > > LakeShen
> > >
> > >
> >

Reply via email to