Do you have server logs for the period of time when you were observing
"Blocked system-critical thread has been detected" error on the client?
--
Sent from: http://apache-ignite-users.70518.x6.nabble.com/
Hi!
Thanks a lot for your reply.
I am absolutely sure that all ports are open and hosts are reachable
because:
1) It had been working before
2) I was able to ping all other nodes from the client host while it was
stucked
3) It started working after restart
Any ideas?
--
Sent from: http://apa
Hi,
GridGain checks that each critical worker thread is is alive and updating
its heartbeat timestamp. If that is not the case, the worker will be
regarded as blocked and GridGain will print a message to the log file. The
period of inactivity is specified by the
IgniteConfiguration.systemWorkerBl
Hi guys!
I have ignite cluster of 3 nodes and couple of applications with enabled
client mode and default communication spi configuration. One morning I found
one of applications being stucked with following messages in the log:
I was able to connect to the server via ssh, no connectivity probl