Hello!
I think it will. You can probably check it - try removing these
configurations, see if extra PMEs disappear.
Regards,
--
Ilya Kasnacheev
пт, 5 февр. 2021 г. в 13:36, Shiva Kumar :
> Hi Ilya,
> In my case i have cache group configuration as attached in the config file
> and connecting t
Hi Ilya,
In my case i have cache group configuration as attached in the config file
and connecting to visor using this config file, does this config cause PME ?
Regards,
Shiva
On Fri, Feb 5, 2021 at 3:42 PM Ilya Kasnacheev
wrote:
> Hello!
>
> Do you have any caches defined in client configurati
Hello!
Do you have any caches defined in client configuration? If you have any
caches there then PME will be triggered.
Regards,
--
Ilya Kasnacheev
чт, 4 февр. 2021 г. в 14:37, Shiva Kumar :
> Even i observed the same, during thick client or visor joining cluster
> looks like something relate
Even i observed the same, during thick client or visor joining cluster
looks like something related to PME happens but not data rebalancing, and
also it is putting some lock on WAL archive segment which never gets
released and causing WAL disk running out of space.
On Thu, 4 Feb, 2021, 4:59 pm Hem
Hi, can anyone please check and respond on this..appreciate your help in
advance
--
Sent from: http://apache-ignite-users.70518.x6.nabble.com/
https://cwiki.apache.org/confluence/display/IGNITE/%28Partition+Map%29+Exchange+-+under+the+hood
As per the documentation, if we are using apache ignite thick client 2.8 and
above, it should not trigger PME in server nodes. But it does not look like
it is skipping, I see below logs
INFO 2021-02-