Re: Parrallel Flow Controller AAE unable to reconnect to its remote delegates after ActiveMQ failure

2012-03-05 Thread Jaroslaw Cwiklik
After you restart the broker, do you send another CAS to the remote and does it fail for the same reason? JC On Fri, Mar 2, 2012 at 9:59 AM, Spico Florin wrote: > Hello! > I have a pipeline that is using the AdvancedFixedFlowController.xml. > After shooting down the ActiveMQ Broker and restar

Parrallel Flow Controller AAE unable to reconnect to its remote delegates after ActiveMQ failure

2012-03-02 Thread Spico Florin
Hello! I have a pipeline that is using the AdvancedFixedFlowController.xml. After shooting down the ActiveMQ Broker and restarting after a while, the I've gotten the message: org.apache.uima.adapter.jms.client.BaseUIMAAsynchronousEngineCommon_impl handleException INFO: Received Exception In Mes