VMWare 5.1 errors with 4.1

2013-03-26 Thread Francois Gaudreault
Hi, We compiled the 4.1 latest code today, and when we try to add a zone with a VMWare cluster, we end up with this error: INFO [network.vpc.VpcManagerImpl] (VpcChecker-1:) Found 0 removed VPCs to cleanup INFO [hypervisor.vmware.VmwareServerDiscoverer] (catalina-exec-14:) Discover host. dc

Re: VMWare 5.1 errors with 4.1

2013-03-26 Thread Francois Gaudreault
I should give a bit more details here. Our vCenter contains other DataCenter, and we give administrative rights to the cloudstack user only to a specific DC. Is that sufficient? Do we need top-level privileges for adding custom fields? Francois On Tue, Mar 26, 2013 at 4:17 PM, Francois Gaudre

Re: VMWare 5.1 errors with 4.1

2013-03-26 Thread Kirk Kosinski
Hi, Francois. CloudStack needs admin rights at the vCenter server level, not just at the datacenter level. The "Unable to setup custom field facility" error indicates a lack of needed permissions. Best regards, Kirk On 03/26/2013 01:36 PM, Francois Gaudreault wrote: > I should give a bit more d

Re: VMWare 5.1 errors with 4.1

2013-03-27 Thread Francois Gaudreault
Hi Kirk, Thanks for the pointers. We manage to get it done without giving full top level permissions. So far, giving only "set" and "modify custom attributes" rights seems to be sufficient. We will see with future usage :) Thanks! Francois On Tue, Mar 26, 2013 at 6:34 PM, Kirk Kosinski wrot