Re: [ClusterLabs] Two node cluster goes into split brain scenario during CPU intensive tasks

2019-06-23 Thread Emmanuel Gelati
Hi, Please, specify which you running and and check the cpu usage of your system, if you we are talking about user usage or system usage. Best regards Il giorno dom 23 giu 2019 alle ore 13:40 Somanath Jeeva < somanath.je...@ericsson.com> ha scritto: > Hi All, > > I have a two node cluster with

Re: [ClusterLabs] Question on sharing data with DRDB

2019-03-20 Thread Emmanuel Gelati
If you need to access from both nodes, you need to use primary/primary mode in drbd Il giorno mer 20 mar 2019 alle ore 16:51 JCA <1.41...@gmail.com> ha scritto: > OK, thanks. Yet another thing I was not aware of in the clustering world > :-( > > On Wed, Mar 20, 2019 at 9:41 AM Valentin Vidic > w

Re: [ClusterLabs] Redundant ring not recovering after node is back

2018-08-22 Thread Emmanuel Gelati
Sorry a Typo I think you are mixing interface with nodelist http://clusterlabs.org/ pacemaker/doc/en-US/Pacemaker/1.1/html/Clusters_from_ Scratch/_sample_corosync_configuration.html 2018-08-22 22:20 GMT+02:00 Emmanuel Gelati : > I think you are missing interface with nodelist h

Re: [ClusterLabs] Redundant ring not recovering after node is back

2018-08-22 Thread Emmanuel Gelati
I think you are missing interface with nodelist http://clusterlabs.org/pacemaker/doc/en-US/Pacemaker/1.1/html/Clusters_from_Scratch/_sample_corosync_configuration.html 2018-08-22 14:53 GMT+02:00 David Tolosa : > Hello, > Im getting crazy about this problem, that I expect to resolve here, with > y

Re: [ClusterLabs] Fence agent executing thousands of API calls per hour

2018-08-01 Thread Emmanuel Gelati
Maybe you need to use pcs resource update 2018-08-01 22:26 GMT+02:00 Casey & Gina : > How is the interval adjusted? Based on an example I found online, I > thought `pcs resource op monitor interval=15m vmware_fence` should work, > but after executing that `pcs config` still shows a monitor in

Re: [ClusterLabs] STONITH resources on wrong nodes

2018-07-11 Thread Emmanuel Gelati
You need to use location l_ston_pg3 p_ston_pg3 inf: pg3, because -inf is negative. 2018-07-11 18:44 GMT+02:00 Salvatore D'angelo : > Hi all, > > in my cluster doing cam_mon -1ARrf I noticed my STONITH resources are not > correctly located: > p_ston_pg1 (stonith:external/ipmi): Started pg2 > p_sto

Re: [ClusterLabs] VM failure during shutdown

2018-06-26 Thread Emmanuel Gelati
I think that you need pcs resource create windows_VM_res VirtualDomain hypervisor="qemu:///system" config="/opt/sigma_vms/xml_definitions/windows_VM.xml" meta target-role=Stopped In this way, pacemaker doesn't starts the resources 2018-06-26 17:24 GMT+02:00 Vaggelis Papastavros : > Many thanks