Can you check this old thread : https://forums.centos.org/viewtopic.php?t=65539
Theoretically El7 vs EL8 drbd cluster should not be different. Maybe you missed
something. Also try with the simplest drbd conf possible and if it starst
working - try to add option by option to identify which is
I always start w/ the bare minimum. From there I've added a bit more
(e.g. stonith) to see what it's behavior was. My experience w/ DRBD has
been solid and always worked w/ everything from Centos 5 through Centos
7. Centos 8 is a different animal. Haven't gotten that to work. I have a
feeling
Maybe. I haven't focused on any stickiness w/ which node is generally
master or not. Going standby on the master node should move the slave to
master. I'm just trying to follow what's been tried and true in the past
and it's no longer following what I would expect. About the only change
is the
On 1/15/21 10:10 PM, Brent Jensen wrote:
pacemaker-attrd[7671]: notice: Setting master-drbd0[nfs5]: 1 -> 1000
I wonder: Does that mean the stickiness for master is still 1000 on nfs5?
___