2017-02-27 Thread Jose Vela Delgado
Thank you so much Michael. I already got it. It works perfect. Regards, Jose Vela *Técnico de Networking Routing y Switching.* Mira mi perfil profesional y conecta conmigo en LinkedIn pinchando en este enlace.

Re: Problem with Event 0 BOOTSTRAP

2017-02-27 Thread Michael Ducharme
Have you tried adding a precondition for the preset, to only match a value that would be present in the original config and not the autoconfig file? Then it should not rerun the preset. The easiest thing would be to match the vendor config file name: InternetGatewayDevice.DeviceInfo.VendorConf

Re: Problem with Event 0 BOOTSTRAP

2017-02-27 Thread Dan Morphis
0 BOOTSTRAP happens because downloading a new config file causes the CPE to do a factory default to the new config. On Mon, Feb 27, 2017 at 12:41 AM, Jose Vela Delgado wrote: > Hello everyone. > > I have configured 0 BOOTSTRAP event in a PRESET. When you connect a CPE > that comes from the facto

Problem with Event 0 BOOTSTRAP

2017-02-27 Thread Jose Vela Delgado
Hello everyone. I have configured 0 BOOTSTRAP event in a PRESET. When you connect a CPE that comes from the factory, it downloads our autoconfiguration file, that is, that works perfect. The problem is that when the CPE is reinitiated to take the changes, the 0 BOOTSTRAP event continues to appear