Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-07-06 Thread Bogdan-Andrei Iancu
Brett Nemeroff wrote: > On Tue, Jul 6, 2010 at 12:56 PM, Bogdan-Andrei Iancu > mailto:bog...@voice-system.ro>> wrote: > > Basically you cannot do it with the current code - you need a small > patch to make it work. Let me know if it's something like a "live & > death" case and will try

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-07-06 Thread Brett Nemeroff
On Tue, Jul 6, 2010 at 12:56 PM, Bogdan-Andrei Iancu wrote: > Basically you cannot do it with the current code - you need a small > patch to make it work. Let me know if it's something like a "live & > death" case and will try to take a look into it. > > Bogdan, I really do appreciate your enthus

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-07-06 Thread Bogdan-Andrei Iancu
Basically you cannot do it with the current code - you need a small patch to make it work. Let me know if it's something like a "live & death" case and will try to take a look into it. Regards, Bogdan Brett Nemeroff wrote: > On Tue, Jul 6, 2010 at 12:49 PM, Bogdan-Andrei Iancu > mailto:bog...@

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-07-06 Thread Brett Nemeroff
On Tue, Jul 6, 2010 at 12:49 PM, Bogdan-Andrei Iancu wrote: > Hi Brett, > > see the restart_fr_on_each_reply param (default 1) - you need to have it > enabled if you want to change the fr_inv_timer changed at reply time. > > But your problem is the "drop()" - if you drop the reply, the > fr_inv_t

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-07-06 Thread Bogdan-Andrei Iancu
Hi Brett, see the restart_fr_on_each_reply param (default 1) - you need to have it enabled if you want to change the fr_inv_timer changed at reply time. But your problem is the "drop()" - if you drop the reply, the fr_inv_timer will not be re-armed. Regards, Bogdan Brett Nemeroff wrote: > T

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-06-30 Thread Brett Nemeroff
Thanks for the suggestion, but I already have this set!! On Wed, Jun 30, 2010 at 11:13 AM, Richard Revels wrote: > Possibly this? > > AVPs are persistent per SIP transaction, being available in "route", > "branch_route" and "failure_route". To make them available in > "onreply_route" armed via T

Re: [OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-06-30 Thread Richard Revels
Possibly this? AVPs are persistent per SIP transaction, being available in "route", "branch_route" and "failure_route". To make them available in "onreply_route" armed via TM module, set "onreply_avp_mode" parameter of TM module (note that in the default "onreply_route", the AVPs of the transac

[OpenSIPS-Users] Convert 183SDP to 180 fr_inv_timer problem

2010-06-29 Thread Brett Nemeroff
Hello List, Thomas Gelf wrote a nice code snippet that converts a 183 SDP to a 180 in an onreply route. I just tried this out and it works great.. Only one problem. I reset my $avp(s:fr_inv_timer) right before I call it and the change isn't being honored. I'm wondering if it has to do with a t_fu