On Thu, Dec 17, 2015 at 6:45 PM, Nicola Marzari
wrote:
All: we should put a note in the output that states this?
>
or print only half of the k-points in the LSDA case. This is actually what
is done for xml output. It may break some scripts that read the output,
though.
is your system 0-dim ? is it fully relaxed ?
stefano
On 17/12/2015 15:31, yin li wrote:
Dear QE community,
I wonder if there is a rule to choose acoustic sum rule. I set very
tight convergence criterion for both pw.x (conv_thr = 1.0D-10) and
ph.x(tr2_ph=1.0d-16).
When I applied
Dear Ron,
for spin polarized calculations, the two identical k-points are actually
storing
the spin-up and spin-down bands respectively. So it's all good, but indeed
weird looking.
All: we should put a note in the output that states this?
nicola
On
On Thu, Dec 17, 2015 at 12:14 PM, Cohen, Ronald
wrote:
> The attached input gives duplicate k-points:
> with
> K_POINTS automatic
> 2 2 2 0 0 0
>
> number of k points=12 gaussian smearing, width (Ry)= 0.0020
>cart. coord. in units 2pi/alat
The attached input gives duplicate k-points:
with
K_POINTS automatic
2 2 2 0 0 0
number of k points=12 gaussian smearing, width (Ry)= 0.0020
cart. coord. in units 2pi/alat
k(1) = ( 0.000 0.000 0.000), wk = 0.125
k(2) = (
Dear all,
a new version of *AiiDA (v0.5.0) is now available for download*.
You can find more information and download instructions at
http://www.aiida.net/?page_id=264
Also, we are going to hold a *MARVEL/MaX/Psi-k "Tutorial on
high-throughput computations: general methods and applications
On Thursday, December 17, 2015 03:31:02 PM yin li wrote:
> When I applied asr="simple", the frequencies of the first 3 modes are not
> equal to zero, but a relatively small negative value. The low-frequency
> modes are affected, and there is no change in frequency number of
> high-frequency modes.
what is "error in routine adiaghg(707): problem calculating cholesky"? How
it can be resolved? It arises after 7 cycles of relax calculation.
On 17 Dec 2015 9:25 am, "gyanu khatri" wrote:
>
> what is "error in routine adiaghg(707): problem calculating cholesky"? How
> it
Dear QE community,
I wonder if there is a rule to choose acoustic sum rule. I set very tight
convergence criterion for both pw.x (conv_thr = 1.0D-10) and
ph.x(tr2_ph=1.0d-16).
When I applied asr="simple", the frequencies of the first 3 modes are not
equal to zero, but a relatively small negative
Dear Paolo,
Thanks for the hint. The fix you pointed out is correct, it works.
However, I've got another error when compiling pw.x related to the
function esm_cft.f90. Taking advantage of your post, I've looked at
the qe-forge page and found a fix (11758) to the above function at
Dear Dr. Lorenzo Paulatto,
Thank you very much for your kind answer!
Best Regards,
Yin
Dr. Yin Li
Department of Biophysics,Medical School, University of Pecs,
No.12 Szigeti Street, Pecs, H-7624, HUNGARY
Phone: +36-72-535271/36271
___
Pw_forum
Hi,
May be because, you have changed ecutrho from 320 Ry (in scf) to 160 Ry
(in nscf).
Surender Kumar
> Dear all,
>
> I am now calculating the DOS of CsPbI3 using espresso-5.2.0 and would like
> to know the contribution of each atom. I succeeded in the calculation of
> Pb2+ and I3-, but I
On Thursday, December 17, 2015 09:32:04 AM luca maggi wrote:
> Serial version
> Reading header from file slub_no_hubb.charge
> At line 119 of file plot_io.f90 (unit = 4, file = 'slub_no_hubb.charge')
> Fortran runtime error: Bad integer for item 1 in list input
Well, how did you generate
On Thursday, December 17, 2015 11:04:47 AM yin li wrote:
> Dear QE community,
>
> I wonder what is the unit of the displacement vector in dynamical matrix
> file? alat or angstrom or bohr?
Neither: the displacements are normalized.
How much the atoms move depends on their mass (i.e. there could
Dear QE community,
I wonder what is the unit of the displacement vector in dynamical matrix
file? alat or angstrom or bohr?
For example:
Diagonalizing the dynamical matrix
q = (0.0 0.0 0.0 )
Dear All,
I'm trying to calculate the charge density difference between the same
structure with and without the hubbard correction term. I have calculated
already the charge density for the two structure.
The input file for getting the difference is :
/
iflag = 3 ,
nfile = 2
Hello all,I got this error when I run pp.x to extract charge plot:Error in
routine chdens (1): incompatible gcutm or dual or ecut
ecut and ecutrho are all the same for my systems but I do no know what areĀ
gcutm & dual.
Best,JaretASU___
Pw_forum mailing
You are right. Actually that exit code is issued by mpirun. I should run
pw.x without mpirun to see the pw.x exit code.
Sincerely yours
Parham
On Dec 17, 2015 10:58 AM, "Paolo Giannozzi" wrote:
> 65 is not one of the error codes set by pw.x IIRC. See the header of
>
On Thursday, December 17, 2015 09:25:26 AM gyanu khatri wrote:
> what is "error in routine adiaghg(707): problem calculating cholesky"? How
> it can be resolved? It arises after 7 cycles of relax calculation.
Dear Gyanu,
it is difficult to say without further details.
kind regards
--
Dr.
19 matches