[QE-users] How to calculate water molecule energy at large cell size?

2019-03-14 Thread ? ??
Hello, My question is how to calculate scf energy of water molecule in large cell size of 12 angstrom. The energy cutoff is at 160 ry. The dft method I used is scan. Mixing_beta=0.1 and diagonalization = 'cg’. When the cell size is beyond 16 bohr the program reported ‘too many bands are not

Re: [QE-users] hai,

2019-03-14 Thread Paolo Giannozzi
You are thinking to the so-called "conventional" (simple cubic) cell, but QE uses the "primitive" (smallest) cell Paolo On Thu, Mar 14, 2019 at 7:17 PM yasmin kani wrote: > I can't understand the concept ibrav used in QE. because ibrav=2 defines > fcc lattice. In fcc there are four atoms per

Re: [QE-users] Problem with generating q-points for lambda

2019-03-14 Thread Paolo Giannozzi
I don't think weights are different; one set is normalized, one set is not, but weights are automatically normalized inside the code Paolo On Thu, Mar 14, 2019 at 7:14 PM Arena Konta wrote: > Dear Professors Paolo and and Hari, > > I appreciate your both help. However, I am still a little bit

Re: [QE-users] SCF job Crashed

2019-03-14 Thread Paolo Giannozzi
On Thu, Mar 14, 2019 at 11:32 AM Ubaid Mohd wrote: But sir in some case it works. > and in some it doesn't. So, what should I do for the this type of problems > provide input lattice vectors with more significant digits, or (better) use "ibrav" to set the correct lattice; provide input atomic

Re: [QE-users] Problem with generating q-points for lambda

2019-03-14 Thread Hari Paudyal
Hi, I think, you are on the correct way, but you are taking double points on every k-points (if you add all it is 128 but it should be 4x4x4 = 64). So, take half on each. This can be understood by considering the Gamma (0.0 0.0 0.0) point only, there should be only one Gamma point, no? Best,

[QE-users] hai,

2019-03-14 Thread yasmin kani
I can't understand the concept ibrav used in QE. because ibrav=2 defines fcc lattice. In fcc there are four atoms per unit cell but we give nat=2. why? ___ users mailing list users@lists.quantum-espresso.org

Re: [QE-users] Problem with generating q-points for lambda

2019-03-14 Thread Arena Konta
Dear Professors Paolo and and Hari,   I appreciate your both help. However, I am still a little bit confused which weights should I chose for lambda.x file. For example:   bravais-lattice index =    7 lattice parameter (alat)  =   7.9506  a.u. unit-cell volume  = 

Re: [QE-users] pw_readschema_file failed retrieving input info from xml file ph.x using grid in qe-6.3-bkp and 2D cutoff

2019-03-14 Thread RAPHAEL LONGUINHOS MONTEIRO LOBATO
Hi, Thanks. I will download the modified files, recompile, and test again. Best, Message: 2 > Date: Wed, 13 Mar 2019 20:42:05 +0100 > From: Paolo Giannozzi > To: Quantum Espresso users Forum > Subject: Re: [QE-users] ?Re: pw_readschema_file failed retrieving > input info from xml

Re: [QE-users] SCF job Crashed

2019-03-14 Thread Ubaid Mohd
But sir in some case it works. So, what should I do for the this type of problems because same calculation is running without any error on my PC and it crashing on clustures. *Mohammad Ubaid* *PhD Research Scholar* *Department of Physics* *Jamia Millia Islamia University* *New Delhi - 110025*

Re: [QE-users] SCF job Crashed

2019-03-14 Thread Paolo Giannozzi
It's a frequently reported problem, due to the usage of "ibrav=0" with lattice vectors or atomic positions not exactly symmetric. ibrav=0 should not be used for systems having some symmetry. Paolo On Thu, Mar 14, 2019 at 5:58 AM Ubaid Mohd wrote: > Dear all QE users, > I am doing charge

Re: [QE-users] running error (cannot read atomic specie from: ATOMIC_POSITIONS angstrom)

2019-03-14 Thread Paolo Giannozzi
Actually this is no longer needed: brackets can be there but their presence is not required Paolo On Thu, Mar 14, 2019 at 6:35 AM Stefano Baroni wrote: > “angstrom” should be enclosed in curly brackets, as in “{angstrom}” > SB > ___ > Stefano Baroni, Trieste -- http://stefano.baroni.me > > >

Re: [QE-users] running error (cannot read atomic specie from: ATOMIC_POSITIONS angstrom)

2019-03-14 Thread Paolo Giannozzi
On Thu, Mar 14, 2019 at 4:56 AM Haider Abbas wrote: > > Error in routine card_atomic_species (5010): > cannot read atomic specie from: ATOMIC_POSITIONS angstrom > you should have "ntyp" atomic species in the ATOMIC_SPECIES card, but you have less than that Paolo -- Paolo Giannozzi,