Hello,
My question is how to calculate scf energy of water molecule in large cell size
of 12 angstrom. The energy cutoff is at 160 ry. The dft method I used is scan.
Mixing_beta=0.1 and diagonalization = 'cg’. When the cell size is beyond 16
bohr the program reported ‘too many bands are not
You are thinking to the so-called "conventional" (simple cubic) cell, but
QE uses the "primitive" (smallest) cell
Paolo
On Thu, Mar 14, 2019 at 7:17 PM yasmin kani wrote:
> I can't understand the concept ibrav used in QE. because ibrav=2 defines
> fcc lattice. In fcc there are four atoms per
I don't think weights are different; one set is normalized, one set is not,
but weights are automatically normalized inside the code
Paolo
On Thu, Mar 14, 2019 at 7:14 PM Arena Konta wrote:
> Dear Professors Paolo and and Hari,
>
> I appreciate your both help. However, I am still a little bit
On Thu, Mar 14, 2019 at 11:32 AM Ubaid Mohd wrote:
But sir in some case it works.
>
and in some it doesn't.
So, what should I do for the this type of problems
>
provide input lattice vectors with more significant digits, or (better) use
"ibrav" to set the correct lattice; provide input atomic
Hi,
I think, you are on the correct way, but you are taking double points on
every k-points (if you add all it is 128 but it should be 4x4x4 = 64). So,
take half on each. This can be understood by considering the Gamma (0.0 0.0
0.0) point only, there should be only one Gamma point, no?
Best,
I can't understand the concept ibrav used in QE. because ibrav=2 defines
fcc lattice. In fcc there are four atoms per unit cell but we give nat=2.
why?
___
users mailing list
users@lists.quantum-espresso.org
Dear Professors Paolo and and Hari,
I appreciate your both help. However, I am still a little bit confused which
weights should I chose for lambda.x file. For example:
bravais-lattice index = 7
lattice parameter (alat) = 7.9506 a.u.
unit-cell volume =
Hi,
Thanks. I will download the modified files, recompile, and test again.
Best,
Message: 2
> Date: Wed, 13 Mar 2019 20:42:05 +0100
> From: Paolo Giannozzi
> To: Quantum Espresso users Forum
> Subject: Re: [QE-users] ?Re: pw_readschema_file failed retrieving
> input info from xml
But sir in some case it works. So, what should I do for the this type of
problems because same calculation is running without any error on my PC and
it crashing on clustures.
*Mohammad Ubaid*
*PhD Research Scholar*
*Department of Physics*
*Jamia Millia Islamia University*
*New Delhi - 110025*
It's a frequently reported problem, due to the usage of "ibrav=0" with
lattice vectors or atomic positions not exactly symmetric. ibrav=0 should
not be used for systems having some symmetry.
Paolo
On Thu, Mar 14, 2019 at 5:58 AM Ubaid Mohd wrote:
> Dear all QE users,
> I am doing charge
Actually this is no longer needed: brackets can be there but their presence
is not required
Paolo
On Thu, Mar 14, 2019 at 6:35 AM Stefano Baroni wrote:
> “angstrom” should be enclosed in curly brackets, as in “{angstrom}”
> SB
> ___
> Stefano Baroni, Trieste -- http://stefano.baroni.me
>
> >
On Thu, Mar 14, 2019 at 4:56 AM Haider Abbas
wrote:
>
> Error in routine card_atomic_species (5010):
> cannot read atomic specie from: ATOMIC_POSITIONS angstrom
>
you should have "ntyp" atomic species in the ATOMIC_SPECIES card, but you
have less than that
Paolo
--
Paolo Giannozzi,
12 matches
Mail list logo