Hello Michal,
the pw.x code always uses symmetry to reduce the number of k-points, never
to reduce the number of atoms. Whatever it does, it profusely writes to
output (especially if you set verbosity='high'.
regards
--
Lorenzo Paulatto
On Sat, 5 Dec 2020, 11:13 Husak Michal, wrote:
> Hi
>
>
Dear Sohail,
Why don't you spare us some effort and tell us which error you actually
get, instead of relying on guesswork?
--
Lorenzo Paulatto
On Sat, 5 Dec 2020, 12:59 Sohail Ahmad via users, <
users@lists.quantum-espresso.org> wrote:
> Dear QEusers,
> I am using QE 6.5 and got dispersion cur
This is never going to converge, it is diverging and quite fast actually.
Check your system geometry and electronic properties (band structure, gap)
Regards
--
Lorenzo Paulatto
On Sat, 5 Dec 2020, 17:50 Dr. K. C. Bhamu, wrote:
> Dear Dr. Lurii
> My phonon band structure was not converged in 1
Dear Dr. Lurii
My phonon band structure was not converged in 100 cycles.
I am getting below message in last few iterations:
Pert. # 1: Fermi energy shift (Ry) =-3.1160E+75-9.3536E+49
iter # 96 total cpu time : 40259.0 secs av.it.: 280.8
thresh= 1.000E-02 alpha_mix = 0
Dear Dr. Jibiao Li
Hello, you are trying to reproduce the room-temperature superconductivity!
You can compute lambda and omega_ln with matdyn.x (w/o lambda.x)
And I strongly recommend to use the tetrahedron method as follows:
scf.inp(pw.x input)
&CONTROL
calculation = 'scf' ,
Dear QE users
I am using QE6.5
while calculating Phonon, sometimes it doesnot get converge even after
iteration # 100,
How to increase "number of iterations" in input "ph.in"
Best Wishes
-
Dr. Sohail Ahmad
Department of Physi
Dear experts,
I am making scratch it's working in the same way as bgw2pw.x.
I have a question on the attributes for wfc file in hdf5 format.
In the case multi processor run.
I often see "igwx" is related with the dimension of "Miller Indices" and
"evc".
But sometimes "igwx" not equal to "ngw" wh
Dear QEusers,
I am using QE 6.5 and got dispersion curve but it gives error in calculating
phonon dos
pls check input, if there is any error
&input
asr = 'simple',
dos = '.true.',
amass(1) = 51.99,
amass(2) = 28.08,
amass(3) = 58.69,
flfrc = 'NiCrSi.fc',
fldos = 'NiCrSi.phdos',
nk1 = 8,
Dear All,
What's the right procedure to obtain Tc of a crystal in QE? To calculate
Tc, I followed the sequence in example 03 and successfully completed the run of
example 03. However, when I turned to another material (see input below), i was
stopped in the last step calculations using lambda.x
Hi
I have a question to QE developers.
The Material Cloud as well as BURAI gui generate QE files without
information about the cell centering (Bravais lattic).
As the result QE calculates with 2-4x more atoms than neccesary in
the corresponding primitive non-centered unit cell ...
Does it realy
10 matches