Dear Nuttachai,
The two-step procedure for magnetic insulators is needed only if you use the HP
code to compute the Hubbard parameters. But if your goal is to compute the band
structure, then there is no need to use this two-step procedure.
HTH
Iurii
--
Dr. Iurii TIMROV
Senior Research Sc
Dear Users, and developers,
I am using quantum espresso version 7.0 to study the SOC effect on
magnetic insulator (EuO) band structure.
I have no problem with the magnetic insulator band structure
calculated using LDA+U (without SOC). The procedure I used is the same
as recommended on
https://gitla
Dear Sergey
DFT-D3 is a semiempirical pairwise correction to forces added on top
of the Hellmann-Feynman forces. You should be safely able to use HP to
calculate the ab initio U correction without D3 and then add again the
D3 correction to optimize your structure in a DFT+U+D3 fashion. If