Hi All, I’d like to know if a noncollinear calculation can be started from a collinear wfc. I always get “Error in routine read_wfc (29): cannot open restart file run/run.save/wfc1 for reading”.
I tried a few things like 1. nosym=.true. and noinv=.true. in the collinear calculation, to make sure I have the same k-points as in the noncollinear. 2. Also, I tried NOT using LDA+U as I see that collinear runs need lda_plus_u_kind=0 while noncollinear ones need lda_plus_u_kind=1. So I thought I’d ask, maybe it’s just not implemented? Thanks in advance, Ignacio Martin Alliati PhD candidate, Maths and Physics, Queen’s University Belfast.
_______________________________________________ Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso) users mailing list users@lists.quantum-espresso.org https://lists.quantum-espresso.org/mailman/listinfo/users