Re: [QE-users] Trouble reading Atomic Positions from CIF file

2018-11-05 Thread Aziz Fall
Dear Tone Kokalj, Thank You very much Sincerely Aziz Fall On Sun, Nov 4, 2018 at 5:02 AM Tone Kokalj wrote: > Dear Aziz > > Note that xcrysden is not able to parse "crystal_sg" coordinates in the > pw.x input file. Do a "dry" pw.x run on your input and then visualize > the output instead. > >

Re: [QE-users] Trouble reading Atomic Positions from CIF file

2018-11-04 Thread Tone Kokalj
Dear Aziz Note that xcrysden is not able to parse "crystal_sg" coordinates in the pw.x input file. Do a "dry" pw.x run on your input and then visualize the output instead. Best regards, Tone -- J. Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia (tel: +386-1-477-3523 // fax: +386-1-251-938

Re: [QE-users] Trouble reading Atomic Positions from CIF file

2018-11-03 Thread Aziz Fall
Dear Pietro Davide Delugas Thank you very much for your kind reply. I tried running the input file you sent me using xcrysden, but I get a weird error saying that the line = CR 3A 0.4 At line 328 of file pwi2xsf.f Fortran runtime error: Bad real number in item 1 of list input I have tried re-

Re: [QE-users] Trouble reading Atomic Positions from CIF file

2018-10-31 Thread Pietro Davide Delugas
Dear Aziz you can use the CIF file coordinates directly   using the crystal_sg format for the coordinates in atomic positions, and specify the space_group number in the system namelist ( please look at the input documentation ). This information is all contained in the CIF file. You were als

[QE-users] Trouble reading Atomic Positions from CIF file

2018-10-30 Thread Aziz Fall
Dear Quantum Espresso team, I am a researcher from the University of Michigan Ann Arbor. I am still fairly new to Quantum Espresso. I have been recently trying to run a band structure calculation of CrI3. The first step I took was to write the scf input file for CrI3 and plug in all of the cell pa