Re: [QE-users] ibrav -13

2020-09-26 Thread Carlo Nervi
Forgot to mention that I used Quantum Espresso 6.6. Il giorno sab 26 set 2020 alle ore 00:23 Carlo Nervi ha scritto: > > Dear QE developers, > I have a problem with ibrav -13. > The volume compute at first is too small from what it should be from a cif > file and differs if I run with ibrav=0 >

Re: [QE-users] ibrav -13

2020-09-26 Thread Paolo Giannozzi
I think that the cif file and ibrav=0 case refer to the "conventional" cell, while the ibrav=-13 case is for the "primitive" cell. The former has twice the number of atoms of the latter, in addition to twice the volume. Using the information on the space group number and Wyckoff positions

[QE-users] ibrav -13

2020-09-25 Thread Carlo Nervi
Dear QE developers, I have a problem with ibrav -13. The volume compute at first is too small from what it should be from a cif file and differs if I run with ibrav=0 Attached please find the cif file, the input with ibrav=-13 and with ibrav=0 With ibrav=-13 the first volume is computed as

Re: [QE-users] ibrav -13 for version 6.5

2020-06-01 Thread Paolo Giannozzi
You are right, I exchanged "old" and "now" Paolo On Mon, Jun 1, 2020 at 10:09 AM S S R R Perumal wrote: > Hi, > What I see from the pw documentation that > > https://www.quantum-espresso.org/Doc/INPUT_PW.html > > that for ibrav -13 options definition of the cell matrix is defined with >

[QE-users] ibrav -13 for version 6.5

2020-06-01 Thread S S R R Perumal
Hi, What I see from the pw documentation that https://www.quantum-espresso.org/Doc/INPUT_PW.html that for ibrav -13 options definition of the cell matrix is defined with respect to old version as "v1(old) = v2(now), v2(old) = -v1(now)" but by comparing the output from version 6.5 and 6.3