On 2022-07-27 12:22, Federico Civerchia wrote:
Yes, errors with UHD benchmarks, ping packet loss and iperf3 packet
loss on both setups.
The patch cables are new and 3mt long (always bought from FS)
Federico
Is this two different N310 on two different computers, or a single N310
on two comp
Yes, errors with UHD benchmarks, ping packet loss and iperf3 packet loss
on both setups.
The patch cables are new and 3mt long (always bought from FS)
Federico
On 27/07/22 18:18, Marcus D. Leech wrote:
On 2022-07-27 12:15, Federico Civerchia wrote:
Hi Rob, Marcus,
thank you for your answer
On 2022-07-27 12:15, Federico Civerchia wrote:
Hi Rob, Marcus,
thank you for your answers.
Yes, I have packet loss with ping and also with iperf3 (considering
udp) at low rates (500Mb, 1Gb).
From the host side I can also see continuous disconnection and
re-connection of the link. For the Int
Hi Rob, Marcus,
thank you for your answers.
Yes, I have packet loss with ping and also with iperf3 (considering udp)
at low rates (500Mb, 1Gb).
From the host side I can also see continuous disconnection and
re-connection of the link. For the Intel X520-DA2 NIC, I have bought
Intel SFP+ (E10GS
On 2022-07-27 11:30, Rob Kossler wrote:
Hi Federico,
I have several N310s and different types of 10Gb links: direct attach
copper, multi-mode (850nm), single mode (1310nm). All have worked
well including the transceivers from lower cost vendors such as FS and
GTek. I have also used the X520-D
Hi Federico,
I have several N310s and different types of 10Gb links: direct attach
copper, multi-mode (850nm), single mode (1310nm). All have worked well
including the transceivers from lower cost vendors such as FS and GTek. I
have also used the X520-DA2. So, while it is possible that your
trans
Dear Community,
I have recently bought two new Ettus N310 and I have started to verify
the connection with the hosts. The NIC interfaces mounted in the hosts
are Intel X520-DA2 and Broadcom BCM57414 NetXtreme-E 10Gb/25Gb.
Unfortunately, the benchmark for both USRP fails or I have errors like
On 2022-07-26 19:35, Giuseppe Santaromita wrote:
Dear community,
I am trying to use OpenAirInterface with an N310 as gNB. I am writing
on this mail list because I think my problem is caused by the
configuration of the N310.
When I run the N310 I get variable errors. When I run it for the fir
On 2022-07-26 19:51 +, skyung--- via USRP-users wrote:
> However, it still give me the “ERROR_CODE_OVERFLOW (Out of sequence
> error)”.
>
> Currently, the USRP is connected to the host via switch. Do you think
> I need to configure the switch in any specific way?
If you have a configurable sw