Get you last good catalog backup and do a restore, then make sure you
don't fiddle with the Authorization section of the NBU without first
reading and making sure you truly understand what the is going on. It
appears you have successfully restricted everyone from the
administrative feature. In t
I hope somebody can help me. Support is flailing. No help at all.
I made a few changes via the console GUI and now I don't have
access to any of the admin commands. When I crank up the GUI, all I get
is the Backup, Archive and Restore menu option. I get this whether I'm
at my w
I have come across a weird problem today.
I am runnin NBU 6.0 MP4 in a windows environment. I tried to do an
inventory of my library (Adic Scalar I2000) and it never completed soI
cancelled it but it is continually sending a request to the library. Is
there a file that is telling the server that
Our Solaris 9 Master Server is running NB_5.1 MP6 on a V480.
What I want to do is to bring up Solaris 10 on a T2000, install NB_5.1 MP6
then upgrade to NB_6.0MP4. I heard that it would be better to upgrade
Netbackup on the existing server then transfer to the T2000, but there is
not enough disk o
BackupExec released a device driver for this library on 2/26/2007, did you
install it?
http://seer.support.veritas.com/docs/286523.htm
I haven't worked with BE since 10d, but IF Be's drivers don't support the
device, then you MIGHT be able to get by with manufacturer / Microsoft drivers,
but
> Are there any naming convention rules on scripts created to
> backup the archive logs?
>
> I've come across the following problem:
>
> - When initiating a backup it fails with error 29
> (failed trying to execute a command).
>
> - The script it calls is named: brarchive_svc
Whenever you execute a command within a script, it's usually best to
specify the complete path to the executable you want to run, so there is
no ambiguity.
ie, if you want to run /opt/myscript/bin/test, rather than
/usr/bin/test, then be specific.
Paul
--
> -Original Message-
> From:
Sorry
5.1 MP6
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Clooney,
David
Sent: 01 June 2007 12:34
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] Slow catalog backup
Hi All
Scenario
Master server Solaris 8 64 bit
We recently moved out
Hi All
Scenario
Master server Solaris 8 64 bit
We recently moved out catalog from local disk to SAN attached LUN, since
then the catalog backup is taking hours compared to what is used to.
We decided to take a copy of the catalog within a NBU policy to see the
results, as this would make full u
Hello rajkorada
Try to raise the CLIENT_CONNECT_TIMEOUT and CLIENT_READ_TIMEOUT, these is
DWORD values under \HKEY_LOCAL_MACHINE\SOFTWARE\Veritas\Netbackup\..\Config
Regards
Michael
On Thu, 31 May 2007 19:22:04 -0700, rajkorada wrote
> Hi There,
>
> My daily scheduled full backup of SQL DB's a
10 matches