Re: [Veritas-bu] NBU 7.6.0.1 and Appliance 2.6.0.1

2014-01-27 Thread Mikhail Nikitin
The only caveat of the 7.5.0.7 patch is that you can't upgrade 7.5.0.7 to 7.6 yet. So, if anyone is planning upgrade to 7.6 soon - do not install 7.5.0.7 Best regards, Mikhail On 28/01/2014 8:35 am, "tsimerson" wrote: > Finally able to get to Symantec web sites. The issue with the TIR pruning

[Veritas-bu] NBU 7.6.0.1 and Appliance 2.6.0.1

2014-01-27 Thread tsimerson
Finally able to get to Symantec web sites. The issue with the TIR pruning not working correctly is isolated to 7.5.0.6. There is a specific EEB that you can get to patch either NBU 7.5.0.6 or appliance version 2.5.3. The other solution is to patch up to NBU 7.5.0.7 or appliance version 2.5.4.

[Veritas-bu] NBU 7.6.0.1 and Appliance 2.6.0.1

2014-01-27 Thread tsimerson
Actually, there are two significant database changes. The EMM database is being upgraded from Sybase 11 to Sybase 12. This is one of the causes for lengthy upgrades. This process (I believe) is to actually dump the database, upgrade Sybase and then reload the database. This is where if you h

Re: [Veritas-bu] Netbackup With Data Domain,

2014-01-27 Thread Mikhail Nikitin
Hi Sunil, I believe you can use DD Boost over FC between media server and DD. With NetWorker you can use ClientDirect with FC, too if memory serves me well. However, DDs can't replicate over FC atm, you have to use 1 or 10 gig links to replicate data. Of course you need DD OS 5.4+, DD Boost plug-

[Veritas-bu] Netbackup With Data Domain

2014-01-27 Thread Sunil Gulati
Hello, Can we use DDboost feature over FC ? Like I have production and a DR site in my environment. I have data domain & netbackup media servers at both location. I have kept tape library at my primary site for tape outs. I want to use SLP which will run 4 backup jobs (Backup, Replication, Impor