Hey Steve,
I can confidently say if drives are lost from the O/S where a cfgadm or a 
reboot is needed to see them again NBU has absolutely nothing to do with it. Do 
you lose /dev/rmt entries? Can you see the drives in the output of a scan 
command? You might want to verify the persistant binding settings for the HBA 
card.

+----------------------------------------------------------------------
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu