Re: [Veritas-bu] Blocksize problem after upgrading EMC powerpath ( UPDATE)

2006-01-19 Thread william . d . brown
To veritas-bu@mailman.eng.auburn.edu cc Subject [Veritas-bu] Blocksize problem after upgrading EMC powerpath ( UPDATE) Hello All I have now by trial and error figured out that it wasn't EMC powerpath, but Windows 2003 SP1 which puts a microsoft hbaapi.dll into system32 in place

[Veritas-bu] Blocksize problem after upgrading EMC powerpath (UPDATE)

2006-01-18 Thread ida3248b
Hello All I have now by trial and error figured out that it wasn't EMC powerpath, but Windows 2003 SP1 which puts a microsoft hbaapi.dll into system32 in place of the emulex one. At the moment there's hbaapi.dll (from microsoft, 64Kb limit) and emulexhbaapi.dll (at least 256kb) in system32 on