: Friday, October 05, 2007 2:49 PM
To: veritas-bu@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU 6.0 MP5 unable to read old catalog. Solairs 9
Hi,
I just upgrade the NBU from 5.1 to 6.0 MP5 around 2 weeks ago. I found
the 6.0 does not read my catalog order than 30 days. I have set
'Compress ca
Yes, there is a bug in 6.0MP5 with catalog compression, which is why I did
not upgrade the environment in which I use catalog compression to 6.0MP5
yet. I suggest you open a case with Symantec on how to fix it if
possible.
Justin.
On Fri, 5 Oct 2007, Koping Wang wrote:
> Hi,
> I just upgrade
Hi,
I just upgrade the NBU from 5.1 to 6.0 MP5 around 2 weeks ago. I found
the 6.0 does not read my catalog order than 30 days. I have set
'Compress catalog interval after 30 days' in my Global Attribute. My
catalog was text. Did any body see this issue before?
The OS is Solaris 9
Thanks
Koping