On Thu, 5 Mar 2009, Dave Markham wrote:
Netbackup 5.0MP7 running on Solaris with SL24
Guys i got a bit of weird issue i wondered if anyone could shed some
light on.
A customer is changing from an L1000 to an SL24, but wants to have the
L1000 configured also for historic restores until
1. So you took the tapes from the L1000 and put them into an SL24?
No, The new unit is LTO3 and we have brand new tapes with new barcodes.
The reason i have restored catalogue is so we have historic data. My
idea was to hook up the L1000 when we transfer this server down,
configure it and then
Dude i totally didn't read to the bottom of your email.
Thats exactly what has happened. Its now working.
Fantastic. What a star.
How would i have found that out? Dear me.
Cheers
Justin Piszcz wrote:
On Thu, 5 Mar 2009, Dave Markham wrote:
Netbackup 5.0MP7 running on Solaris with
: Thu, 05 Mar 2009 14:06:28 +
From: Dave Markham dave.mark...@fjserv.net
Subject: Re: [Veritas-bu] Strange problem after changing storage unit.
To: Justin Piszcz jpis...@lucidpixels.com
Cc: veritas-bu@mailman.eng.auburn.edu
veritas-bu@mailman.eng.auburn.edu
Message-ID: 49afdc64.5090
: Thursday, March 05, 2009 8:05 AM
To: Justin Piszcz
Cc: veritas-bu@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Strange problem after changing storage unit.
1. So you took the tapes from the L1000 and put them into an SL24?
No, The new unit is LTO3 and we have brand new tapes with new barcodes
Manager
office:
mobile:
Message: 13
Date: Thu, 05 Mar 2009 14:06:28 +
From: Dave Markham dave.mark...@fjserv.net
Subject: Re: [Veritas-bu] Strange problem after changing storage unit.
To: Justin Piszcz jpis...@lucidpixels.com
Cc: veritas-bu@mailman.eng.auburn.edu