Re: [Veritas-vx] CFS/CVM/VCS Interconnect speed

2007-03-14 Thread Engle, Victor
Thanks Jim, I have noticed that it is always the v440 with ce interfaces used for the interconnect that gets fenced out and forced into a panic. The 280r's use qfe's and never get fenced out. All interfaces link at 100 full duplex. I am using 2 switches for the interconnect. Does anyone know of p

Re: [Veritas-vx] CFS/CVM/VCS Interconnect speed

2007-03-14 Thread Shelton, Darren
ce interfaces typically don't negotiate properly down to 100meg. Double check your ce.conf (or write a startupscript and use ndd) and make sure that you are setting the ce's to 100fdx. darren -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Engle, Victo

[Veritas-vx] VEA GUI Documentation and SF 5.0

2007-03-14 Thread Paul Hunter
I am looking for any docs to install, configure and start the VEA GUI for Storage Foundation Suite 5.0. Thanks ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx

Re: [Veritas-vx] VEA GUI Documentation and SF 5.0

2007-03-14 Thread Frank Currie
Hi Paul, Are you talking about standard VEA or the Storage Foundation Management Server (http://www.symantec.com/sfms)? Setup for VEA in 5.0 should be the same as 4.x except that there is the new pal agents as well as vxsvc. Regards, Frank. From: [EMA