Darren,
Thanks a lot for your help.
On 11/13/07, A Darren Dunham <[EMAIL PROTECTED]> wrote:
> On Tue, Nov 13, 2007 at 09:04:12AM -0500, Aleksandr Nepomnyashchiy wrote:
> > > > SENA1_6 sliceddatadg_new1 datadg online
> > > > SENA1_7 sliceddatadg_new2 datadg online
>
Two options:
1. use a command from the database edition that provides this sort of
mapping:
vxstorage_stats
Although this command was targeted at the database market, it works on
any file.
The requirements and such are in chapter ~8 of the DBED Administrator's
Guide. Man page below. Note that, at
On Tue, Nov 13, 2007 at 09:04:12AM -0500, Aleksandr Nepomnyashchiy wrote:
> > > SENA1_6 sliceddatadg_new1 datadg online
> > > SENA1_7 sliceddatadg_new2 datadg online
So the disks are online...
> /[EMAIL PROTECTED],4000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0(ses
Hello,
we have Sparc/Solaris 10 + VSF 4.1 + hardware array and one concatenated volume:
drozd:/root# vxprint -htg drozd-whiskey2-dg
DG NAME NCONFIG NLOG MINORS GROUP-ID
ST NAME STATEDM_CNT SPARE_CNT APPVOL_CNT
DM NAME DEVICE TYPE PRIV
Darren,
Thank you for your answer.
On 11/12/07, A Darren Dunham <[EMAIL PROTECTED]> wrote:
> On Mon, Nov 12, 2007 at 08:08:36PM -0500, Aleksandr Nepomnyashchiy wrote:
> > On several volumes vxprint shows:
> >
> > v volumename DISABLED ACTIVE
> > pl volumename-01 DISABLED IOFAIL
> > pl volumename