You might want to check whether or not the OS is seeing the disks properly (
SAN/whatever was under veritas control ). Also check /etc/path_to_inst. Do a
'reconfig reboot'
On Sat, Sep 26, 2009 at 9:23 AM, milind phanse wrote:
> Hi All,
>
> I have below query. Our server which was under veritas
Hi Doug
yes, i could do it manually. But there are so many volumes and so many hosts
to check..i thought a script would be helpful
Regards
Ajay
On Mon, Sep 7, 2009 at 10:30 PM, Doug Hughes wrote:
> ajay raghuraj wrote:
>
>> Hi
>> I am looking for some veritas scripts on
Hi
I am looking for some veritas scripts on the net which will help me
determine which plex has subdisks coming from two different arrays in a host
based mirrored config.
Volume_xxx
Plex0
SD1
SD2
Plex1
SD3
SD4
SD1/2 are concatenated normally coming from one array and SD3/4 from
another. The prob
Hi
I am looking for some veritas scripts on the net which will help me
determine which plex has subdisks coming from two different arrays in a host
based mirrored config.
Volume_xxx
Plex0
SD1
SD2
Plex1
SD3
SD4
SD1/2 are concatenated normally coming from one array and SD3/4 from
another. The prob
It is supported ..at least in SF HA 4.x. At the end of the day a diskgroup
is afterall a resource from a VCS perspective.
we have had this kind of a configuration ..one service group with two
diskgroups. Bascially two databases in one service group. Each database
having its own diskgroup/volumes
Hi,
It looks like multipathing is missing . But I am not sure where it is
enabled . Is it in veritas / powerpath / native as this is Sol 10. On Sol 10
how do we check multipathing as been enabled or not ? Is it some option with
stmsboot ?
Secondly if I have to enable it in veritas , how do i do i
Yes, but the disks should be made available from the storage side as well.
Only then will the SAs be able to perform import/deport operations on the
DG. My comments are w.r.t EMC . I do not know how it will handle disks from
other storage vendors. But i would definetely want to know how it is
con
Hi,
I had a problem recently with an upgrade of a solaris machine. It was a
patch upgrade . After the task, all my emc LUNs were renamed . 'emcpower1a'
became 'emcpower7a' and so on. Luckily I had 'volnamed' the devices via
format ad hence could fix the mounts in vfstab. But I wasnt able to restor
Hi,
I had a problem recently with an upgrade of a solaris machine. It was a
patch upgrade . After the task, all my emc LUNs were renamed . 'emcpower1a'
became 'emcpower7a' and so on. Luckily I had 'volnamed' the devices via
format ad hence could fix the mounts in vfstab. But I wasnt able to restor
* [EMAIL PROTECTED] [mailto:
> [EMAIL PROTECTED] *On Behalf Of *ajay raghuraj
> *Sent:* Tuesday, August 14, 2007 1:21 PM
> *To:* veritas-vx@mailman.eng.auburn.edu
> *Subject:* [Veritas-vx] mirroring existing volume
>
>
> Hi All,
>
>
> I created a volume consisting of a si
Hi All,
I created a volume consisting of a single plex and subdisk with vxassist. I
am looking to mirror it now. The storage person has allocated me another
disk of the same size . I intend to make a subdisk and plex and then attach
it to the existing volume . Will this activity serve my purpose
Hi All,
I created a volume consisting of a single plex and subdisk with vxassist. I
am looking to mirror it now. The storage person has allocated me another
disk of the same size . I intend to make a subdisk and plex and then attach
it to the existing volume . Will this activity serve my purpose ?
Hi,
I need some help on clusters . Basically I tried to switchover a group from
NodeA to NodeB. The status for the group was STOPPING|PARTIAL for a long
time and nothing was progressing in the engine logs. I decided to revert it
by running
"hagrp -flush -sys NodeA"
The status changed to PARTI
well if you have discovered the LUNs...then :
1. add /initialize the disk in veritas
/etc/vx/bin/vxdisksetup -i c#t#d#
vxdisk -o alldgs list --> check status
2. add the disk into the dg, assuming emcdg
vxdg -g emcdg adddisk =
if you do not want to use it as hotspare , then u need to set the n
Hello Bryan,
Clicking on the URL gives this error. Can you send the document as an
attachment please?
Error 500--Internal Server Error From RFC 2068 *Hypertext Transfer
Protocol -- HTTP/1.1*: 10.5.1 500 Internal Server Error
The server encountered an unexpected condition which prevented it fr
sorry i forgot to copy the group in . Awaiting your reponses. Thanks
-Ajay
-- Forwarded message --
From: ajay raghuraj <[EMAIL PROTECTED]>
Date: Jan 1, 2007 9:20 PM
Subject: Re: [Veritas-vx] discover EMC storage
To: Deepak John Cutinha <[EMAIL PROTECTED]>
I re
set of disks on 2 different paths for redundancy
and load balacing
--
*From:* [EMAIL PROTECTED] [mailto:
[EMAIL PROTECTED] *On Behalf Of *ajay raghuraj
*Sent:* Wednesday, November 29, 2006 10:06 AM
*To:* Veritas-vx@mailman.eng.auburn.edu
*Subject:* [Veritas-vx] discov
Hi,
I am new to EMC . I was asked to resize a filesystem in veritas , the
storage team allocated a 20Gb LUN . This is what I saw when I discovered
the new disks. I am confused here, what actually is the LUN size
allocated? Is it 20 Gb really or more?Please advise. Any documents that i
can refe
18 matches