Re: [vpp-dev] Change interface default MTU to 1500

2020-02-26 Thread Greg O'Rawe
Certainly in VPP 17.01 jumbo frames were not handled properly by VPP and in our application we had to reset the MTU in VPP to be 1500 via something like: set interface mtu 1500 device_37/0/0 Greg From: vpp-dev@lists.fd.io On Behalf Of John Lo (loj) via Lists.Fd.Io Sent: 26 February 2020

[vpp-dev] LACP bonding with VPP and SR-IOV

2020-02-21 Thread Greg O'Rawe
Hi, Has anyone any experience of using LACP bonding with VPP in a bifurcated setup via SR-IOV? I'm using VPP 19.08. My environment uses Mellanox ConnectX-4 25Gbps NICs in a single bond which carries data and control plane traffic via separate VLANs. It is not possible to have control plane

[vpp-dev] Failover not working on X520 NIC with ixgbevf driver

2019-11-27 Thread Greg O'Rawe
reported in the /var/log/messages files on either the VM or the hypervisor machines. Any ideas on this issue? Thanks Greg O'Rawe This message, including attachments, is CONFIDENTIAL. It may also be privileged or otherwise protected by law. If you received this email by mistake please let us