URL:
<http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20090829/fcf6e299/attachment.htm>
I2/m is a non-standard setting of the space group C2/m, N. 12 of the
International Tables. You have first to check which direction is your
monoclinic unique axis in the I2/m setting you are using.
Then, you can use for instance the program SETSTRU from the Bilbao
Crystallographic Server (www.c
In case.in2 (not case.in2_st) TEMPS will include the Fermi-Dirac
(electronic) contribution. At least at room temperature this is
probably smaller than the phonon contribution.
Not sure about your second question. In principle all terms such as
this are included in the energy and I doubt that it is
It sounds like the programs did not compile correctly. Try (from $WIENROOT)
grep -i "error" */compile.msg | grep -v arguments |grep -v know
or
grep -i "error" */compile.msg
These should both show nothing if everything worked. If they did not,
look at the appropriate compile.msg file. Probably you
Yep, bunch of errors. Well, back to the drawing board..
thanks Laurence
Jonas
[jbaltrus at rs-003 wein2k]$ grep -i "error" */compile.msg | grep -v arguments
|grep -v know
SRC_2Doptimize/compile.msg:make: *** [fminenefitcoa.o] Error 127
SRC_afminput/compile.msg:make: *** [afminput.o] Error 127
S
5 matches
Mail list logo