As far as I understand, Mac OS has a default soft limit on the stack of 8MB and
a hard limit at a maximum of 64MB. I agree this is a severe limitation.
$ launchctl limit
cpu unlimited unlimited
filesizeunlimited unlimited
dataunli
Hello !
I started to do the Initilization calculation chosing the spin up.
At the step " "check if gmin___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http:
Dear Prof. Blaha,
I will try that, many thanks!
Best wishes,
Bing
From: Peter Blaha
To: A Mailing list for WIEN2k users
Sent: Friday, April 12, 2013 1:34:28 PM
Subject: Re: [Wien] the differences between rhoplot and "gnuplot splot "file
name""
Look into rhoplot !
It uses a small program to
Hi Zaid,
I realised I had made a small mistake in the reply. The
plasmon is defined as where 1 (i.e. the real part) crosses zero with a
positive slope and NOT ε2. ε2 goes to zero at very high energy values when
no valence or semi-core shell excitation is possible. On the contrary ε1
fluctuates
I am working on the Wien2k 11.1 version with the intent of doing some
band gap engineering in ZnSiAs2 (struct file attached).
For using the mBJ potential, I first initialized and ran a complete scf
cycle using PBE with zero errors.
As suggested in the UG, I then created .inm_vresp file, edited .
I could debug the problem with XMCD for large cells.
There were (at least) 2 severe bugs:
In subroutine sph-UPcor.frcchange the allocation of
NCG1(22) --> ncg1(nat)
(this was the reason that one could run only cases up to 22 atoms).
In subroutine mmatcv.f there was another p
Dear Wien2k users,
I am working on the Wien2k 11.1 version with the intent of doing some band gap
engineering in ZnSiAs2 (struct file attached).
For using the mBJ potential, I first initialized and ran a complete scf cycle
using PBE with zero errors.
As suggested in the UG, I then created .inm
good afternoon sir,
my usb dive is not detect during installation of Ubuntu 11.10 pls help me
and suggest me to overcome this problem.
with regards-
Jyoti
R/s
kuk
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac
Respected Kulpreet
I appreciate the way you explained my question. Thank you for suggesting
books.
Thank you so much.
Best Regard's
M. Zain
On Fri, Apr 12, 2013 at 3:17 PM, Kulpreet Virdi <
kulpreet.vi...@cup.uni-muenchen.de> wrote:
> Hi Zaid,
>
>
>
> yes, one way of identifying the Plasmon (e
Hi Zaid,
yes, one way of identifying the Plasmon (energy) is the
maximum in loss function (electron energy loss plot) however this is not
always correct. The loss function is given by Im [-1/ε] which is equal to
[ε2/(ε1^2+ε2^2)]. In the loss function you would see a maximum when there
is a loca
10 matches