Thank you very much Sir, I got it now!
On Friday 26 January 2018, 2:19:45 AM IST, Stefaan Cottenier
wrote:
For phonons, it is important to have very precise forces. The precision of
forces depends on the basis set size (rkmax). You can test for a much
For phonons, it is important to have very precise forces. The precision of
forces depends on the basis set size (rkmax). You can test for a much smaller
supercell how large rkmax needs to be in order to have sufficiently precise
forces, and then use immediately that rkmax for your large system.
Thank you very much Sir,
My last query is: In the SrTiO3 exercise Peter Sir used rkmax 6 while for band
structure rkmax 6 for SrTiO3 is less (sorry, I missed that exercise otherwise I
wanted to put it here).
So, does the rkmax in phonopy has the same importance as in the band
structure?My
Using run_lapw -fc 0.1 is fine. The -fc does not mean that positions will be
optimized. It means that at the end of the scf cycle full forces will be
calculated, and forces is what you want to know in a phonon calculation.
You must not use min_lapw or run_lapw -min, as these will optimize the
Almost certainly lapw1 failed. When you have an error, you should always do:
1) cat *.error
2) Look at the end of the relevant output files.
Without other information I doubt that anyone can say more, there are
many possibilities.
On Thu, Jan 25, 2018 at 9:37 AM, mostefa djermouni
Dear Peter BLAHA and WIEN2K users,
I have 80-atoms calculation and after the first cycle of SCF, I got this error :
LAPW0 END
LAPW1 END
LAPW1 END
forrtl: severe (67): input statement requires too much data, unit 10, file
/home/mostefa/WIEN2k/NOURIA/PFN_17.1/PFN_SCF/PFN/./PFN.vectorup
Image
6 matches
Mail list logo