No
On Saturday 2018-08-04 16:22, Dr. K. C. Bhamu wrote:
Date: Sat, 4 Aug 2018 16:22:20
From: Dr. K. C. Bhamu
Reply-To: A Mailing list for WIEN2k users
To: A Mailing list for WIEN2k users
Subject: Re: [Wien] regarding mixing parameter in hybrid calculations
Thanks Dr. Tran,
My mistake,
Thanks Dr. Tran,
My mistake, the standard value is 0.25!!
Yes, I saw the link you provided (response was on my own queries).
What is advised there is:
"What you get from the optic calculation (the case.epsilon) file is only
the electronic part (and not even the whole electronic part) of
Hi,
First, the standard value is 0.25 and not 0.025.
For the dielectric constant, there was alreday some explanations here:
https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg14936.html
https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg14875.html
alpha_opt at V=V_exp
Dear Dr. Tran,
In the recent past, I did some calculations using YS-PBE0 for MgO and
results were well reproduced (wien2k Exercise).
I just read your paper (J. Phys.: Condens. Matter 25 (2013)) and get to
know that we can control the mixing parameter using various ways.
1) Standard value
4 matches
Mail list logo